readcd - read or write data Compact Discs
The device refers to scsibus/target/lun of the drive. Communication on SunOS is done with the SCSI general driver scg. Other operating systems are using a library simulation of this driver. Possible syntax is: dev= scsibus,target,lun or dev= target,lun. In the latter case, the drive has to be connected to the default SCSI bus of the machine. Scsibus, target and lun are integer numbers. Some operating systems or SCSI transport implementations may require to specify a filename in addition. In this case the correct syntax for the device is: dev= devicename:scsibus,target,lun or dev= devicename:target,lun. If the name of the device node that has been specified on such a system refers to exactly one SCSI device, a shorthand in the form dev= devicename:@ or dev= devicename:@,lun may be used instead of dev= devicename:scsibus,target,lun.
To access remote SCSI devices, you need to prepend the SCSI device name by
a remote device indicator. The remote device indicator is either
REMOTE:user@host:
or
.BIREMOTE:host:
A valid remote SCSI device name may be:
REMOTE:user@host:
to allow remote SCSI bus scanning or
REMOTE:user@host:1,0,0
to access the SCSI device at
host
connected to SCSI bus # 1,target 0 lun 0.
To access SCSI devices via alternate transport layers, you need to prepend the SCSI device name by a transport layer indicator. The transport layer indicator may be something like USCSI: or ATAPI:. To get a list of supported transport layers for your platform, use dev= HELP:
To make readcd portable to all UNIX platforms, the syntax dev= devicename:scsibus,target,lun is preferred as is hides OS specific knowledge about device names from the user. A specific OS must not necessarily support a way to specify a real device file name nor a way to specify scsibus,target,lun.
Scsibus 0 is the default SCSI bus on the machine. Watch the boot messages for more information or look into /var/adm/messages for more information about the SCSI configuration of your machine. If you have problems to figure out what values for scsibus,target,lun should be used, try the -scanbus option of cdrecord.
If no options except the dev= option have been specified, readcd goes into interactive mode. Select a primary function and then follow the instructions.
On Linux, drives connected to a parallel port adapter are mapped to a virtual SCSI bus. Different adapters are mapped to different targets on this virtual SCSI bus.
If no dev option is present, cdrecord will try to get the device from the CDR_DEVICE environment.
If the argument to the dev= option does not contain the characters ',', '/', '@' or ':', it is interpreted as an label name that may be found in the file /etc/cdrecord.conf (see FILES section).
If you find C2 errors you may want to reduce the speed using the speed= option as C2 errors may be a result of dynamic unbalance on the medium.
Using a lower speed may increase the readability of a CD or DVD.
If no ts= option has been specified, readcd defaults to a transfer size of 256 kB. If libscg gets lower values from the operating system, the value is reduced to the maimum value that is possible with the current operating system. Sometimes, it may help to further reduce the transfer size or to enhance it, but note that it may take a long time to find a better value by experimenting with the ts= option.
For all examples below, it will be assumed that the drive is connected to the primary SCSI bus of the machine. The SCSI target id is set to 2.
To read the complete media from a CD-ROM writing the data to the file cdimage.raw:
readcd dev=2,0 f=cdimage.raw
To read sectors from range 150 ... 10000 from a CD-ROM writing the data to the file cdimage.raw:
readcd dev=2,0 sectors=150-10000 f=cdimage.raw
To write the data from the file cdimage.raw (e.g. a filesystem image from mkisofs) to a DVD-RAM, call:
readcd dev=2,0 -w f=cdimage.raw
Note that this forces cdrecord to create a pipe to the rsh(1) program and disallows cdrecord to directly access the network socket to the remote server. This makes it impossible to set up performance parameters and slows down the connection compared to a root initiated rcmd(3) connection.
If you don't want to allow users to become root on your system, readcd may safely be installed suid root. This allows all users or a group of users with no root privileges to use readcd. Readcd in this case will only allow access to CD-ROM type drives- To give all user access to use readcd, enter:
chown root /usr/local/bin/readcd
chmod 4711 /usr/local/bin/readcd
To give a restricted group of users access to readcd enter:
chown root /usr/local/bin/readcd
chgrp cdburners /usr/local/bin/readcd
chmod 4710 /usr/local/bin/readcd
and add a group cdburners on your system.
Never give write permissions for non root users to the /dev/scg? devices unless you would allow anybody to read/write/format all your disks.
You should not connect old drives that do not support disconnect/reconnect to either the SCSI bus that is connected to the CD-Recorder or the source disk.
When using readcd with the broken Linux SCSI generic driver. You should note that readcd uses a hack, that tries to emulate the functionality of the scg driver. Unfortunately, the sg driver on Linux has several severe bugs:
A typical error message for a SCSI command looks like:
readcd: I/O error. test unit ready: scsi sendcmd: no error CDB: 00 20 00 00 00 00 status: 0x2 (CHECK CONDITION) Sense Bytes: 70 00 05 00 00 00 00 0A 00 00 00 00 25 00 00 00 00 00 Sense Key: 0x5 Illegal Request, Segment 0 Sense Code: 0x25 Qual 0x00 (logical unit not supported) Fru 0x0 Sense flags: Blk 0 (not valid) cmd finished after 0.002s timeout 40s
The second line prints the SCSI command descriptor block for the failed command.
The third line gives information on the SCSI status code returned by the command, if the transport of the command succeeds. This is error information from the SCSI device.
The fourth line is a hex dump of the auto request sense information for the command.
The fifth line is the error text for the sense key if available, followed by the segment number that is only valid if the command was a copy command. If the error message is not directly related to the current command, the text deferred error is appended.
The sixth line is the error text for the sense code and the sense qualifier if available. If the type of the device is known, the sense data is decoded from tables in scsierrs.c . The text is followed by the error value for a field replaceable unit.
The seventh line prints the block number that is related to the failed command and text for several error flags. The block number may not be valid.
The eight line reports the timeout set up for this command and the time that the command really needed to complete.
other-cdwrite-request@lists.debian.organd include the word subscribe in the body. The mail address of the list is:
cdwrite@lists.debian.org
Joerg Schilling Seestr. 110 D-13353 Berlin Germany
Additional information can be found on:
http://www.fokus.fhg.de/usr/schilling/cdrecord.html
If you have support questions, send them to:
cdrecord-support@berlios.de
or
other-cdwrite@lists.debian.org
If you have definitely found a bug, send a mail to:
cdrecord-developers@berlios.de
or
schilling@fokus.fhg.de
To subscribe, use:
http://lists.berlios.de/mailman/listinfo/cdrecord-developers
or
http://lists.berlios.de/mailman/listinfo/cdrecord-support
Закладки на сайте Проследить за страницей |
Created 1996-2024 by Maxim Chirkov Добавить, Поддержать, Вебмастеру |