    NAME

    ieee1284_read_data, ieee1284_write_data, ieee1284_data_dir, ieee1284_wait_data - control the data lines
     
    

    SYNOPSIS

    #include <ieee1284.h>

    int ieee1284_read_data (struct parport *port);
    void ieee1284_write_data (struct parport *port, unsigned char dt);
    int ieee1284_data_dir (struct parport *port, int reverse);
    int ieee1284_wait_data (struct parport *port, unsigned char mask, unsigned char val, struct timeval *timeout);

     

    DESCRIPTION

    These functions manipulate the data lines of the parallel port associated with port (which must have been claimed using ieee1284_claim(3)). The lines are represented by an 8-bit number (one line per bit) and a direction. The data lines are driven as a group; they may be all host-driven (forward direction) or not (reverse direction). When the peripheral is driving them the host must not.

    For ieee1284_data_dir the reverse parameter should be zero to turn the data line drivers on and non-zero to turn them off. Some port types may be unable to switch off the data line drivers.

    Setting the data lines may have side effects on some port types (for example, some Amiga ports pulse nStrobe).

    ieee1284_wait_data waits, up until the timeout, for the data bits specified in mask to have the corresponding values in val.

     

    RETURN VALUE

    ieee1284_read_data returns the 8-bit number representing the data lines unless it is not possible to return such a value with this port type, in which case it returns an error code. Possible error codes:

    E1284_NOTAVAIL
    Bi-directional data lines are not available on this system.

    E1284_INVALIDPORT
    The port parameter is invalid (perhaps it has not been claimed, for instance).

    E1284_SYS
    There was an error at the operating system level, and errno has been set accordingly.

    E1284_TIMEDOUT
    The timeout has elapsed.

    Whereas ieee1284_read_data may return E1284_NOTAVAIL on its first invocation on the port, if it does not do so then it cannot until ieee1284_close is called for that port.

     

    AUTHOR

    Tim Waugh <twaugh@redhat.com>.


     

    Index

    NAME
    SYNOPSIS
    DESCRIPTION
    RETURN VALUE
    AUTHOR


    Поиск по тексту MAN-ов: 




    Партнёры:
    PostgresPro
    Inferno Solutions
    Hosting by Hoster.ru
    Хостинг:

    Закладки на сайте
    Проследить за страницей
    Created 1996-2024 by Maxim Chirkov
    Добавить, Поддержать, Вебмастеру